Inspection
Burglar Alarm Relay
Check for continuity between the terminals.
1.
There should be continuity between the No.5 and No.13 terminals when power and ground are connected to the No.5 and No.3 in the ICM-A.
Rear Wiper Relay
Check for continuity between the terminals.
1.
There should be continuity between the No.14 and No.20 terminals when power and ground are connected to the No.12 and No.16 in the ICM-A.
Folding Motor Relay
Check for continuity between the terminals.
1.
There should be continuity between the No.15 and No.18 terminals when power and ground are connected to the No.2 and No.5 in the ICM-B.
Unfolding Motor Relay
Check for continuity between the terminals.
1.
There should be continuity between the No.13 and No.17 terminals when power and ground are connected to the No.14 and No.5 in the ICM-B.
Door Lock Actuator Relay
Check for continuity between the terminals.
1.
There should be continuity between the No.4 and No.12 terminals when power and ground are connected to the No.3 and No.1 in the ICM-B.
Turn Signal Sound Relay
Check for continuity between the terminals.
1.
There should be continuity between the No.15 and No.18 terminals when power and ground are connected to the No.17 and No.6 in the ICM-A.
ICM (Integrated Circuit Module) Relay Box Description and operation
Description The ICM relay is united with (buglar alarm relay, rear wiper relay, fold/unfold motor relay, turn signal sound relay, rear fog relay, door lock actuator relay, head l ...

Indicators And Gauges
...

Other information:

Kia Carens RP (2013-2018) Service Manual: Specifications


Specifications Items Specifications Rated voltage 5V Load Max. 1mA (When head lamp lighting) Illuminations (LUX) 50 1.42 ± 0.31V 100 ...

Kia Carens RP (2013-2018) Service Manual: Specifications


Specifications Item Specifications Working voltage  DC 12V  Operating force 9.8 ± 2.9N (1.0 ± 0.3kg, 7.2 ± 0.7lb) Working temperature -40°C ~ 80°C (-4 ...

Copyright © www.kicaman.com 2015-2021