Kia Carens: Engine Control System / Purge Control Solenoid Valve (PCSV) Description and operation
Purge Control Solenoid Valve (PCSV) is installed on the surge tank and controls
the passage between the canister and the intake manifold. It is a solenoid valve
and is open when the ECM grounds the valve control line. When the passage is
open (PCSV ON), fuel vapor stored in the canister is transferred to the intake
manifold.

Inspection
1.
Turn the ignition switch OFF.
2.
Disconnect the injector connector.
3.
Measure resistance b ...
Specification
Item
Specification
Coil Resistance (Ω)
22.0 ~ 26.0 [20°C(68°F)]
...
Other information:
Specification
Alternator
Item
Specification
Rated voltage
13.5V, 110A
Speed in use
1,000 ~ 18,000 rpm
Voltage regulator
IC Regulator built-in type
...
Normal Maintenance Schedule
- For Europe (Except Russia)
The following maintenance services must be performed to ensure good emission
control and performance. Keepreceipts for all vehicle emission services to protect
your warranty. Where both mileage and time are shown, the ...