Kia Carens: Engine Control System / Purge Control Solenoid Valve (PCSV) Description and operation
Purge Control Solenoid Valve (PCSV) is installed on the surge tank and controls
the passage between the canister and the intake manifold. It is a solenoid valve
and is open when the ECM grounds the valve control line. When the passage is
open (PCSV ON), fuel vapor stored in the canister is transferred to the intake
manifold.

Inspection
1.
Turn the ignition switch OFF.
2.
Disconnect the injector connector.
3.
Measure resistance b ...
Specification
Item
Specification
Coil Resistance (Ω)
22.0 ~ 26.0 [20°C(68°F)]
...
Other information:
Removal
1.
Disconnect the battery negative cable, and wait for at least thirty
seconds before beginning work.
2.
To remove the emergency fastening device (C), keep on pushing the lock
pin (A) as arrow direction. And then remo ...
Description
•
SS-A solenoid valve is ON/OFF type.
•
When TCM supplies variable current to solenoid valve, speed range is
changed by operating the solenoid valve.
SS-A Solenoid Valve operation table
...