Kia Carens: Intake And Exhaust System / Exhaust Manifold Repair procedures

Kia Carens RP (2013-2018) Service Manual / Engine Mechanical System / Intake And Exhaust System / Exhaust Manifold Repair procedures

Removal and Installation
1.
Remove the engine cover.
2.
Disconnect the battery negative terminal.
3.
Disconnect the front and rear oxygen sensor connectors (A).

4.
Remove the front muffler.
(Refer to Intake And Exhaust System - "Muffler")
5.
Remove the heat protector (A).
Tightening torque:
9.8 ~ 11.8 N.m (1.0 ~ 1.2 kgf.m, 7.2 ~ 8.7 lb-ft)

6.
Remove the exhaust manifold stay (A).
Tightening torque:
39.2 ~ 49.0N.m (4.0 ~ 5.0kgf.m, 28.9 ~ 36.2lb-ft)

7.
Remove the exhaust manifold (A) and gasket.
Tightening torque:
29.4 ~ 41.2N.m (3.0 ~ 4.2kgf.m, 21.7 ~ 30.4lb-ft)

  
When installing, replace with a new gasket.
When installing the intake manifold, tighten the nuts with pre-torque first, and then tighten the nuts with specified torque in the sequence shown.

8.
Install in the reverse order of removal.
Exhaust Manifold Components and components location
Components 1. Heat protector 2. Exhaust manifold 3. Gasket 4. Exhaust manifold stay ...

Muffler Components and components location
Components 1. Front muffler 2. Center muffler 3. Main muffler 4. Gasket 5. Hanger ...

Other information:

Kia Carens RP (2013-2018) Service Manual: Spark Plug Repair procedures


Inspection [On vehicle inspection] 1. Accelerate the engine to about 3,000 rpm 3 times or more. 2. Remove the spark plug. 3. Check the spark plug visually. If the electrode is dry, th ...

Kia Carens RP (2013-2018) Owners Manual: Window opening and closing


Type A To open or close a window, press down or pull up the front portion of the corresponding switch to the first detent position (5). Type B - Auto up/down window (if equipped) Pressing or pulling up the power window switch momentarily to the second detent position (6) completely lowers or rai ...