Kia Carens: Blower / Blower Resistor (Manual) Repair procedures

Kia Carens RP (2013-2018) Service Manual / Heating,Ventilation And Air Conditioning / Blower / Blower Resistor (Manual) Repair procedures

Inspection
1.
Measure the resistance between the terminals.
2.
The measured resistance is not within specification, the blower resistor must be replaced. (After removing the resistor)

Replacement
1.
Disconnect the negative (-) battery terminal.
2.
Disconnect the connector (A) and then remove the blower resistor (B) after loosening the mounting screws.

3.
Install in the reverse order of removal.
Blower Motor Repair procedures
Inspection 1. Connect the battery voltage and check the blower motor rotation. 2. If the blower motor does not operate well, ...

Field Effect Transistor (DATC) Repair procedures
Inspection 1. Turn the ignition switch ON. 2. Manually operate the control switch and measure the voltage of the blower motor. ...

Other information:

Kia Carens RP (2013-2018) Service Manual: Engine Coolant Temperature Sensor (ECTS) Repair procedures


Inspection 1. Turn the ignition switch OFF. 2. Remove the ECTS (Refer to "Removal"). 3. After immersing the thermistor of the sensor into engine coolant, measure resistance between the ECTS ...

Kia Carens RP (2013-2018) Owners Manual: Checking the coolant level


WARNING Removing radiator cap Never attempt to remove the radiator cap while the engine is operating or hot. Doing so might lead to cooling system and engine damage and could result in serious personal injury from escaping hot coolant or steam. Turn the engine off and wait until it cools dow ...