Kia Carens: Blower / Blower Motor Repair procedures

Kia Carens RP (2013-2018) Service Manual / Heating,Ventilation And Air Conditioning / Blower / Blower Motor Repair procedures

Inspection
1.
Connect the battery voltage and check the blower motor rotation.

2.
If the blower motor does not operate well, substitute with a known-good blower motor and check for proper operation.
3.
Replace the blower motor if it is proved that there is a problem with it.
Replacement
1.
Disconnect the negative (-) battery terminal.
2.
Remove the glove box housing.
(Refer to Body - "Glove Box Housing")
3.
Remove the passenger's side (A) after loosening the screw.

4.
Disconnect the connector (A) and then remove the blower motor (B) after loosening the screws.

5.
Install in the reverse order of removal.
Blower Unit Repair procedures
Replacement 1. Disconnect the negative (-) battery terminal. 2. Recover the refrigerant with a recovery/recycling/charging station. ...

Blower Resistor (Manual) Repair procedures
Inspection 1. Measure the resistance between the terminals. 2. The measured resistance is not within specification, the blower resistor ...

Other information:

Kia Carens RP (2013-2018) Service Manual: Fuel Pressure Regulator Repair procedures


Removal 1. Remove the fuel pump. (Refer to Fuel Delivery System - " Fuel Pump") 2. Disconnect the electric pump wiring connector (A) and the fuel sender connector (B). 3. Re ...

Kia Carens RP (2013-2018) Service Manual: Specifications


Specifications Transaxle model M6CF1 Engine type Gasoline 1.6 GDI Manual transalxe oil Quantity 1.8 ~ 1.9 ℓ (0.48 ~ 0.50 U.S.gal., 1.90 ~ 2.0 U.S. qt., 1.58 ~ 1.67 lmp qt.) ...

Copyright © www.kicaman.com 2015-2022