Kia Carens: Anti-theft System / Siren & ACU(Alarm Control Unit) Specifications

Kia Carens RP (2013-2018) Service Manual / Body Electrical System / Anti-theft System / Siren & ACU(Alarm Control Unit) Specifications

Specifications
Siren & ACU(Alarm control unit)
Item
Specification
Normal operating voltage
DC 12V
Operating voltage range
DC +8V ~ +16V
Operating temperature
-40°C (-40°F) ~ 85°C (185°F)
Dark current
Disarm mode
Max. 0.5mA (at DC 12V)
Arm mode
Max. 2.0mA (at DC 12V)
Current consumption
Alarm mode
Max. 300mA (at DC 12V)

Description and operation
Description Anti theft device Block diagram • BCM : Arming-Disarming data output • SIREN : Siren ON when discon ...