Kia Carens: Air conditioning System / Refrigerant Line Repair procedures

Kia Carens RP (2013-2018) Service Manual / Heating,Ventilation And Air Conditioning / Air conditioning System / Refrigerant Line Repair procedures

Replacement
1.
Discharge refrigerant from the refrigeration system.
2.
Replace faulty tube or hose.
  
Cap the open fittings immediately to keep moisture or dirt out of the system.
3.
Tighten the bolt or nut joint to the specified torque.
  
Connections should not be torque tighter than the specified torque.
4.
Evacuate air in the refrigeration system and charge system with refrigerant.
Specified amount
550 ± 25g (19.4 ± 0.88oz.)
5.
Inspect for leakage of refrigerant.
Using a gas leak detector, check for refrigerant leakage.
6.
Inspect A/C operation.
Compressor oil Repair procedures
Oil Specification 1. The HFC-134a or HFO-1234yf system requires synthetic (PAG) compressor oil whereas the R-12 system requires mineral compressor oil. The two ...

Compressor Description and operation
Description The compressor is the power unit of the A/C system. It is located on the side of engine block and driven by a V-belt of the engine. The compressor changes low pr ...

Other information:

Kia Carens RP (2013-2018) Owners Manual: Driving in the rain


Rain and wet roads can make driving dangerous, especially if you’re not prepared for the slick pavement. Here are a few things to consider when driving in the rain: A heavy rainfall will make it harder to see and will increase the distance needed to stop your vehicle, so slow down. Keep your ...

Kia Carens RP (2013-2018) Service Manual: Engine Control Module (ECM) Schematic diagrams


Harness Connector [M/T] ECM Terminal Function (M/T) Connector [C100-AM] Pin No. Description Connected to 1 Injector (Cylinder #3) [High] control output Injector (Cylinder #3) ...

Copyright © www.kicaman.com 2015-2024