Kia Carens: Air conditioning System / Refrigerant Line Repair procedures

Kia Carens RP (2013-2018) Service Manual / Heating,Ventilation And Air Conditioning / Air conditioning System / Refrigerant Line Repair procedures

Replacement
1.
Discharge refrigerant from the refrigeration system.
2.
Replace faulty tube or hose.
  
Cap the open fittings immediately to keep moisture or dirt out of the system.
3.
Tighten the bolt or nut joint to the specified torque.
  
Connections should not be torque tighter than the specified torque.
4.
Evacuate air in the refrigeration system and charge system with refrigerant.
Specified amount
550 ± 25g (19.4 ± 0.88oz.)
5.
Inspect for leakage of refrigerant.
Using a gas leak detector, check for refrigerant leakage.
6.
Inspect A/C operation.
Compressor oil Repair procedures
Oil Specification 1. The HFC-134a or HFO-1234yf system requires synthetic (PAG) compressor oil whereas the R-12 system requires mineral compressor oil. The two ...

Compressor Description and operation
Description The compressor is the power unit of the A/C system. It is located on the side of engine block and driven by a V-belt of the engine. The compressor changes low pr ...

Other information:

Kia Carens RP (2013-2018) Owners Manual: Engine coolant


The high-pressure cooling system has a reservoir filled with year-round antifreeze coolant. The reservoir is filled at the factory. Check the antifreeze protection and coolant concentration level at least once a year, at the beginning of the winter season, and before traveling to a colder climate ...

Kia Carens RP (2013-2018) Service Manual: Seat Heater Switch Repair procedures


Removal First Row Seat 1. Disconnect the negative (-) battery terminal. 2. Remove the console front complete assembly. (Refer to Body - "Floor Console Assembly") 3. Disconnect the mu ...

Copyright © www.kicaman.com 2015-2021