Kia Carens: Engine Control System / CVVT Oil Control Valve (OCV) Repair procedures
1. |
Turn the ignition switch OFF.
|
2. |
Disconnect the OCV connector.
|
3. |
Measure resistance between the OCV terminals 1 and 2.
|
4. |
Check that the resistance is within the specification.
Specification: Refer to “Specification”
|
|
1. |
Turn the ignition switch OFF and disconnect the battery negative (-)
cable.
|
2. |
Disconnect the CVVT oil control valve connector (A).
|
3. |
Remove the installation bolt (B), and then remove the valve from the
engine.
[Bank 1 / Intake]
[Bank 1 / Exhaust]
|
• |
Install the component with the specified torques.
|
• |
Note that internal damage may occur when the component is dropped.
If the component has been dropped, inspect before installing.
|
|
• |
Apply engine oil to the valve O-ring.
|
|
1. |
Installation is reverse of removal.
CVVT oil control valve installation bolt:
9.8 ~ 11.8 N.m (1.0 ~ 1.2 kgf.m, 7.2 ~ 8.7 lb-ft)
|
|
Circuit Diagram
(M/T)
(A/T)
...
Description
Variable Intake manifold Solenoid (VIS) valve is installed on the intake manifold.
The VIS valve controls the vacuum modulator which activates a valve in the intake
m ...
Other information:
Removal
Door Mirror Turn Signal Lamp
1.
Disconnect the negative (-) battery terminal.
2.
Remove the mirror holder (A) from the outside mirror assembly.
...
Removal
1.
Disconnect the negative (-) battery terminal.
2.
Remove the front left door trim.
(Refer to Body - "Front Door Trim")
3.
Remove the power window bezzel assembly (A) after loos ...