Kia Carens: Cooling System / Cooling Fan Description and operation

Kia Carens RP (2013-2018) Service Manual / Engine Mechanical System / Cooling System / Cooling Fan Description and operation

Description
[Air conditioning type]
The cooling fan operates in 2 stages (HIGH/LOW). The engine control module (ECM) controls the cooling fan according to the coolant temperature, vehicle speed and A/C operation.
[Cooling fan operation conditions]
A/C switch
A/C pressure
[kgf/cm² G (psi G)]
Vehicle speed
[km/h (mph)]
Coolant temperature
[°C (°F)]
Cooling fan speed
OFF

V < 45 (28)
95 ~ 100 (203 ~ 212)
LOW
100 (212) or above
HIGH
45 (28) ≤ V < 80 (49.7)
95 ~ 100 (203 ~ 212)
LOW
100 (212) or above
HIGH
80 (49.7) ≤ V
105 (221) or above
HIGH
ON
P < 6 (85.3)
All
105 (221) or above
HIGH
6 (85.3) ≤ P < 12 (170.7)
V < 45 (28)
45 ~ 100 (113 ~ 212)
LOW
100 (212) or above
HIGH
45 (28) ≤ V < 80 (49.7)
95 ~ 100 (203 ~ 212)
LOW
100 (212) or above
HIGH
80 (49.7) ≤ V
105 (221) or above
HIGH
12 (170.7) ≤ P < 15.5 (120.5)
V < 45 (28)
-30 ~ 95 (-22 ~ 203)
LOW
95 (203) or above
HIGH
45 (28) ≤ V < 80 (49.7)
95 ~ 100 (203 ~ 212)
LOW
100 (212) or above
HIGH
80 (49.7) ≤ V
105 (221) or above
HIGH
15.5 (120.5) ≤ P
All
-30 (-22) or above
HIGH

[Non-Air conditioning type]
The cooling fan operates in 1 stages (HIGH). The engine control module (ECM) controls the cooling fan according to the coolant temperature, vehicle speed and A/C operation.
[Cooling fan operation conditions]
A/C switch
A/C pressure
[kgf/cm² G (psi G)]
Vehicle speed
[km/h (mph)]
Coolant temperature
[°C (°F)]
Cooling fan speed
OFF

V < 45 (28)
95 ~ 100 (203 ~ 212) or above
HIGH
45 (28) ≤ V < 80 (49.7)
95 ~ 100 (203 ~ 212) or above
HIGH
80 (49.7) ≤ V
105 (221) or above
HIGH

Cooling Fan Components and components location
Components 1. Cooling fan 2. Fan motor 3. Cooling fan shroud 4. Cooling fan resistor ...

Cooling Fan Specifications
Specifications Item Specification Motor capacity (W) 170 230 Fan type Puller ...

Other information:

Kia Carens RP (2013-2018) Service Manual: Input Speed Sensor Specifications


Specifications ▷ Type: Hall effect sensor Operation condition [°C(°F)] ((-)40 ~ 150)) -40 ~ 302 Air gap(mm)in. (1.2 ~ 1.8) 0.0472 ~ 0.0709 Output voltage(V) High 1.18 ~ 1.68 ...

Kia Carens RP (2013-2018) Service Manual: Components and components location


Components [Without EPB] 1. Guide rod bolt 2. Bleed screw 3. Caliper carrier 4. Caliper body 5. Brake pad 6. Pad retainer 7. Pad return spring Components [With EPB] 1. Guide rod bolt 2. Bleed screw ...

Copyright © www.kicaman.com 2015-2025